Approved
Document F1
Ventilation in Domestic Dwellings
Domestic Buildings
For background ventilation, a ventilation opening (or openings), eg trickle
ventilators, air bricks with a "hit and miss" ventilator, or
where the appropriate, suitably designed opening windows. The Ventilation
opening(s) should be reasonably secure, adjustable and located (typically
1.75m above the floor level) so as to avoid discomfort due to cold draughts
and to prevent rain ingress.
|
Ventilation of rooms containing openable
windows (ie located in an external wall)
|
| Room |
Background
ventilation(1) |
 |
|
Habitable
room
|
8000mm2
|
 |
| Kitchen |
4000mm2
|
 |
| Utility
room |
4000mm2
|
 |
| Bathroom
(with or without WC) |
4000mm2
|
 |
| Sanitary
accomodation (separate from bathroom) |
4000mm2
|
 |
Notes:
1. As an alternative approach to the provisions listed in Table 1, the
overall provision for background ventilation for the dwelling should be
equivalent to an average of 6000mm2 per room for the rooms listed in Table
1, with a minimum provision of 4000mm2 in each room.
Approved
Document E
Resistance to passage of sound (2003 Edition)
Approved
Document L1
Conservation of fuel and power in dwellings (2002 Edition)
Approved
Document L2
Conservation of fuel and power in non-domestic buildings (2002 Edition)
Approved
Document J
Heat Producing Devices (2002 Edition)
|